Lead/lead compounds: Potassium, carbides, sulfides, peroxides, phosphorus, sulfur.
Guide Product Name: Sealed Lead Acid Battery SDS Prepared by: Technical Compliance Consultants (NZ) Ltd Date of SDS: 13 June 2023 Tel: 64 9 475 5240 MATERIAL OR INGREDIENTS Content (wt %) CAS # Lead/Lead Oxide (Litharge)/Lead Sulfate 60-70 7439-92-1 Calcium (lead calcium alloy) <0.15 7440-70-2 Tin <1 7440-31-5
Guide PRODUCT NAME: Lead Acid Battery Wet, Filled With Acid OTHER PRODUCT NAMES: Electric Storage Battery, SLI or Industrial Battery, UN2794 MANUFACTURER: East 99/45/EC-Preparation Labelling, 2001/58/EC-MSDS Content, and 1907/2006/EC-REACH), and an MSDS/SDS is required for
Guide SAFETY DATA SHEET LEAD ACID BATTERY, WET, FILLED WITH ACID Document SDS-02207 Rev No. 3 Date 11/09/19 Page 1 of 8 1. PRODUCT IDENTIFICATION Product Name Lead Acid Battery, Wet Other Names Batteries, wet, filled with acid, Electric storage, Enhanced flood batteries, Idle-Stop-Start wet batteries Use Automotive, Industrial Standby Power and Motive
Guide Lead: Remove from exposure, gargle, wash nose and lips; consult physician. Sulfuric Acid: Flush with large amounts of water for at least 15 minutes; remove contaminated clothing completely,
Guide Recycling: Battery must be recycled in accordance with all Federal, state and local regulations. Label Required: Yes Technical Review Date: May 22, 1992 MFR Label Number: None Label Status: F Common Name: Lead/Acid Battery Signal Word: DANGER! Acute Health Hazard-Severe: X Contact Hazard-Severe: X Fire Hazard-None: X Reactivity Hazard-None: X
Guide Lead Compounds: Inhalation of lead dust or fumes may cause irritation of upper respiratory tract and lungs. Ingestion: Sulfuric Acid: May cause severe irritation of mouth, throat, esophagus and stomach. Lead Compounds: Acute ingestion may cause abdominal pain, nausea, vomiting, diarrhea and severe cramping. This may lead rapidly to systemic
Guide SEALED LEAD ACID BATTERY MATERIAL SAFETY DATA SHEET LEAD-ACID BATTERY - BATTERY ASSEMBLY, LEAD ACID, SEALED, WET CHARGED Ingredient: SULFURIC ACID (SARA III) Ingredient Sequence Number: 01 Percent: 32-40 NIOSH (RTECS) Number: WS5600000 CAS Number: 7664-93-9
Guide A way of repairing a damaged battery case, tested in long term use. Help out: https://
Guide LEAD-ACID BATTERY FILLED WITH ACID 1. IDENTIFICATION PRODUCT NAME: Lead/acid Battery, Wet, filled with acid / Wet cell battery / Flooded battery Distributor: Interstate Batteries,
Guide Electrolyte (Sulfuric acid) IDLH 15 mg/m3 (CAS 7664-93-9) Lead and lead compounds IDLH 100 mg/m3 (inorganic) (CAS 7439-92-1) US. NIOSH: Pocket Guide to Chemical Hazards Components Type Value Antimony (CAS 7440-36-0) TWA 0.5 mg/m3 Lead Acid Battery Wet, Filled With Acid SDS US 967663 Version #: 01 Revision date: - Issue date: 06-February-2024 3 / 10
Guide 3. COMPOSITION / INFORMATION ON INGREDIENTS COMPANY DETAILS PRODUCT NAME Other Name Manufacturer''s Product UN Number Dangerous Goods Class Packing Group Hazchem Code Poisons Schedule Number LEAD ACID BATTERY, WET, FILLED WITH ACID, ELECTRIC STORAGE Battery, Wet, Flooded, Lead Acid Various 2794 8 not assigned 2W S6
Guide SDS sealed lead acid batteries BAE Batterien USA Phone.: 715-247-2262 484 County Road VV Fax: 715-247-5741 Somerset WI, 54025 E-Mail: info@baebatteriesusa Web: Safety Data Sheet . Sealed/valve regulated/non-spillable Lead Acid Battery. SECTION I PRODUCT IDENTIFICATION Manufacturer''s Name:
Guide Industrial Lead Acid Battery Safety Data Sheet Date: 03-29-2022 ECO-103241 ISO Clause: 4.3.1 DCN: SDS-430-00607-07 Page: 1 of 10 1. IDENTIFICATION REVISION DATE: 01-1-2022 Product Name: Lead Acid Battery, Non-Spillable Wet M Synonyms: Industrial Battery, Traction Battery, Stationary Battery, Deep Cycle Battery
Guide Do not use combustible materials. If possible, carefully neutralize spilled acid with soda ash, sodium bicarbonate, lime, etc. Acid must be managed in accordance with approved local, state, and federal requirements. Consult state environmental agency and / or federal EPA. Lead acid batteries are recyclable. Section 7 - Handling and Storage
Guide PS-HTR-ST-43-E_Lead Acid Battery SDS US Version #: 05 Issue Date: 04/01/2015 Revision Date: 03/16/2017 1 of 11 Safety Data Sheet 1. IDENTIFICATION Product Name: Lead Acid Battery Synonyms: SLI Battery Product Use: Vehicle Electrical System Manufacturer/Supplier: Johnson Controls Battery Group Address: P.O. Box 590
Guide Section 12 – Ecological Information bioaccumulation occurs through the food chain. Most studies include lead compounds Section 13- Disposal Considerations requirements in accordance with 40 CFR 266 Subpart G – Spent Lead-Acid Batteries Section 14 – Transport Information U.S. Battery Safety Data Sheet: Lead-Acid Battery, Wet, Electrolyte (Sulfuric Acid) Page 6 of 7
Guide HAZARDOUS DECOMPOSITION PRODUCTS: Lead/Lead compounds: Oxides of lead and sulfur Battery electrolyte (acid): Hydrogen, sulfur dioxide, sulfur trioxide. HAZARDOUS POLYMERIZATION: Will not occur. CONDITIONS TO AVOID: High temperature. Battery
Guide Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals known to cause cancer and reproductive harm, and during charging, strong inorganic acid
Guide MSDS battery MSDS No. L 8A Date Issued Feb. 20, 1990 Date Revised Jan 10, 2005 Chemical/Trade Name (identity used on label) Sealed Lead Acid Battery/ OPTIMA BATTERY TM Chemical Family/Classification Electric Storage Battery HMIS Rating for Sealed, Lead Acid Battery 0 0 0; For sulfuric acid 3 0 2 Synonyms/Common Name Sealed Lead Acid Battery
Guide Lead: Remove from exposure, gargle, wash nose & lips. Consult physician. Sulfuric Acid: Immediately rinse with a large amount of cool water. Rinsing within 1 minute of the burn can
Guide Oxides of lead and sulfur. High temperature, Sparks and other sources of ignition. Prohibit smoking, sparks, etc. from battery charging area. Avoid mixing acid with other
Guide CHEMICAL/TRADE NAME *Lead-Acid Battery Non-spillable (as used on label) Maintenance Free Battery Valve Regulated Battery Sealed Lead-Acid Battery Ingredient: US OSHA US ACGIH US NIOSH Quebec PEV Ontario OEL EU OEL Inorganic forms of: Lead 0.05 0.05 0.05 0.05 0.05 0.15(a) Tin 2 2 2 2 2 2(b)
Guide Valve Regulated Lead-acid Battery (VRLA Battery) SDS No: SDS-CSB-002 Revision: 06.11.2023 Version No: 11.0 Page 1/25 1. Identification. Product identifier : Information on composition and ingredients: NO. Chemical name or common name : Component part . Content rate (mass ratio) Chemical formula . CAS no. 1 . Lead . Terminal, electrode plate
Guide LEAD ACID BATTERY, WET FILLED WITH ACID Document No. SSB-SDS-03, Version 1.3 Product Name: SSB Batteries, Super Start Batteries, Fusion Traction COMPOSITION / INFORMATION ON INGREDIENTS. Page 3 of 8 Issue Date: 1st December 2015 Revision Date: 27th June 2024 First Aid Measures:
Guide Battery Lead Oxide. As the result of this the Risk Phrase R52/53 (Harmful to aquatic organisms, may cause longterm adverse effects in the aquatic environment) applies to Battery Lead Oxide. Effects of Battery Lead Oxide in the aquatic environment: Toxicity for fish: 96 h LC 50 > 100 mg/l Toxicity for daphnia: 48 h EC 50 > 100 mg/l
Guide Disclosed are curable sealant compositions for coating a conductive bushing for a lead-acid cell or battery having positive and negative plates disposed within a container and a cover, the conductive bushing being molded into the cover and providing electrical communication with at least one of the plates, the bushing presenting an interface with the exterior of the bushing and
Guide Non-Spillable Lead Acid Battery Electric Storage Battery Synonyms: Industrial Battery, Traction Battery, Stationary Battery, Telephone: Deep Cycle Battery For information and emergencies, contact EnerSys'' Manufacturer''s Name/Address: Environmental, Health & Safety Dept. at 610-208-1996 EnerSys Canada Corporate Office
Guide COMPOSITION/INFORMATION ON INGREDIENTS. Inorganic lead and sulfuric acid electrolyte are the primary components of every battery manufactured by EnerSys Energy Products.
Guide Industrial/commercial lead acid gel battery. Odorless. Dry chemical, carbon dioxide, water, foam. Do not use water on live electrical circuits. Use appropriate media for surrounding fire. Do not
Guide The materials contained in this product may only represent a hazard if the integrity of the cell or battery is compromised; physically, thermally, or electrically abused. The below are the
Guide U.S. Battery Safety Data Sheet, AGM Batteries - 1 of 7 Safety Data Sheet Non-Spillable, Lead-Acid Battery Revision Date 1/30/2020 Section 1 – Identification. Product Identifier: Lead-Acid Battery, Wet, AGM (Non-Spillable) Electrolyte (Sulfuric Acid) Product Use: Rechargeable Electrical Storage Distributor: U.S. Battery Manufacturing Company
Guide Battery System chooses to manage its spent lead-acid batteries under 40 CFR part 266, subpart G. Recycling: Battery must be recycled in accordance with all Federal, state and local regulations. Label Required: Yes Common Name: Lead/Acid Battery Signal Word: DANGER! Acute Health Hazard-Severe: X Contact Hazard-Severe: X Fire Hazard-None: X
S DOT SHIPPING NAME: Battery, Wet, Non-SpillableAll Interstate Batteries brand and Power Patrol brand sealed lead-acid batteries are “Non-Spillable batteries” as defined by the United States Hazardous Materials Regulations in Title 49 Code of Federal Regulations Part 173.159a and by the Transport Canada Da
Combustion can produce carbon dioxide and carbon monoxide. Use NIOSH approved serf-contained breathing apparatus (SCBA) and full protective equipment operated in positive-pressure mode. Lead acid batteries do not bum, or burn with difficulty. Do not use water on tires where molten metal is present.
Our non-spillable lead acid batteries are under the U.S. Department of Transportation's (DOT) hazardous materials regulations but are excepted from these regulations since they meet all of the following requirements found at 49 CFR 173.159(d) – NMFC # 60680 Class 65.
International Maritime Dangerous Goods (IMDG) Code. Spent lead acid batteries are not regulated as hazardous waste by the EPA when recycled, however state and international regulations may vary. Reportable Quantity (RQ) for spilled 100% sulfuric acid under CERCLA (superfund) and EPCRA (Emergency Planning Community Right to Know Act is 1,000lbs.
welling, corneal damage and irreversible eye damage. plashes of acid in the eyes will cause severe burns.SKIN: Direct contact with acid inside of a battery can be severely irritating to the skin and may resul in redness, swelling, burns and severe skin damage. Skin co tact may aggravate an existing dermatitis co
Contact of battery electrolyte (acid) with the skin may aggravate skin diseases such as eczema and contact dermatitis. Overexposure to sulfuric acid mist may case lung damage and aggravate pulmonary conditions. Sulfuric Acid: Remove to fresh air immediately.
Contact our team for a free feasibility study, custom battery sizing, and a competitive quote.